# Tue Sep 16 05:35:01 2025
#$$PROBEIDENTIFIER=Z114607_0305
#$$PROBENAME=PA BBO 600S3 BBF-H-D-05 Z SP
#$$MAGNETID=BZH0756070H04
#$$CRYOSTATID=D325-54-7373
#$$SHIMID=292722
#
# Active Shim Gradients
#
Z           		-1395           
Z2          		2032            
Z3          		729             
Z4          		-309            
Z5          		252             
Z6          		2021            
Z7          		6220            
Z8          		3021            
X           		-14423          
XZ          		4118            
XZ2         		-3044           
XZ3         		-1438           
XZ4         		-3075           
XZ5         		6843            
Y           		387             
YZ          		-482            
YZ2         		5022            
YZ3         		781             
YZ4         		1427            
YZ5         		-5095           
XY          		5498            
XYZ         		3646            
XYZ2        		-1299           
XYZ3        		-638            
XYZ4        		3229            
XYZ5        		-4358           
(X2-Y2)     		1421            
(X2-Y2)Z    		-8563           
(X2-Y2)Z2   		2019            
(X2-Y2)Z3   		-500            
(X2-Y2)Z4   		-865            
(X2-Y2)Z5   		-29             
X3          		7457            
X3Z         		4079            
Y3          		-6821           
Y3Z         		7964            
#
# Lock Parameter
#
FIELD		5977.163
LOCKPHASE		 112.900
LOCKPOWER		 -27.000
LOCKGAIN		 122.200
LOCKDC		 -75.000
LOCKSHIFT		   7.240
LOOPGAIN		 -12.000
LOOPTIME		   0.400
LOOPFILTER		 100.000
#
IEEE64_VERSION_CODE 1
#
# Shim currents 
#
SHIM_SETTING [ 1]      526.88091601
SHIM_SETTING [ 2]      149.89239991
SHIM_SETTING [ 3]    -2747.75827002
SHIM_SETTING [ 4]     1251.40077737
SHIM_SETTING [ 5]    -1716.77732736
SHIM_SETTING [ 6]     -397.18156944
SHIM_SETTING [ 7]    12188.58939921
SHIM_SETTING [ 8]    -1368.37638258
SHIM_SETTING [ 9]     2987.61692052
SHIM_SETTING [10]     -560.74790802
SHIM_SETTING [11]        0.00000000
SHIM_SETTING [12]   -14784.49665393
SHIM_SETTING [13]     1143.27372022
SHIM_SETTING [14]     1638.53726181
SHIM_SETTING [15]   -12745.98676441
SHIM_SETTING [16]   -23132.75089393
SHIM_SETTING [17]    -4442.91871605
SHIM_SETTING [18]   -14321.24727426
SHIM_SETTING [19]    -1712.08699174
SHIM_SETTING [20]   -14824.63891778
SHIM_SETTING [21]    -6403.56079278
SHIM_SETTING [22]    11477.74627230
SHIM_SETTING [23]    -4922.17628668
SHIM_SETTING [24]     6536.69573316
SHIM_SETTING [25]    -3034.93823574
SHIM_SETTING [26]     1849.82411690
SHIM_SETTING [27]     5594.81838812
SHIM_SETTING [28]     4695.59639299
SHIM_SETTING [29]      632.53187353
SHIM_SETTING [30]     8994.72433747
SHIM_SETTING [31]    -6432.40748063
SHIM_SETTING [32]     7783.60294535
SHIM_SETTING [33]     5647.02919966
SHIM_SETTING [34]     1866.28813105
SHIM_SETTING [35]     4733.90153339
SHIM_SETTING [36]     1705.68625629
SHIM_SETTING [37]     4383.13642858
SHIM_SETTING [38]    -4873.15071424
SHIM_SETTING [39]    -2133.21257658
SHIM_SETTING [40]        0.00000000